Case studies

Reading the signals of water loss with LeakZon

A gap between water entering a district and water recorded by customers can have several causes. Argmax and LeakZon explored how the timing and persistence of that gap can guide a municipal investigation.

Two water meters with clipboards watch a droplet in yellow boots tiptoe away from a dripping pipe.
If only every missing drop wore squeaky boots. AI-generated illustration

Find the hours when water goes unaccounted for

Start with a group of meters served by the same main. For each hour, subtract the total recorded by downstream meters from the volume recorded at the main. A busy afternoon can drive up both totals. What warrants attention is a gap that grows unusually large for that group and stays elevated across consecutive hours.

LeakZon’s theft-detection approach looks for a sustained sequence of peaks in that gap. A sequence that ends gives an investigator a location and a bounded period to review for possible unauthorized use. Before drawing a conclusion, the utility also needs to check whether downstream meters stopped measuring or failed to report. Either can leave legitimate consumption missing from the total.

In a simulated event, the red main-meter trace rises above the blue downstream trace. The difference forms a sustained green peak.
In this simulation, the main meter records more water than the downstream meters. Follow the gap from the raw readings at the top to the green peak at the bottom. Argmax × LeakZon, evaluation on perturbed data · View full size
The main and downstream readings initially fluctuate together. Their smoothed difference briefly wobbles around zero and then flattens.
Compare that peak with this second test series. The two meter traces rise and fall together, and their difference stays close to zero. Argmax × LeakZon, evaluation on perturbed data · View full size

Look for a new overnight baseline

A leak can leave a different trace. Water continues to flow, and a similar amount goes unaccounted for hour after hour. The project’s leakage check examines overnight readings after the suspected start, looking for a recurring level of loss. Repeated returns to nearly zero weaken the case for a continuous leak.

The next comparison is with the same group’s nights before the change. A recurring loss accompanied by a higher overnight average gives the utility a reason to inspect that part of the network. It also provides an estimate of the volume to look for during the inspection.

Compare a consumer with relevant peers

A separate idea in the team’s literature review starts at the customer meter. Group consumers by region and type, estimate the usual range within each group, and flag meters that repeatedly fall outside it. A household and a commercial site can have very different demand patterns even when both meters work correctly.

Choosing comparable groups is the hard part. A poor comparison can make ordinary use look suspicious. Used alongside the main-meter balance and overnight history, a peer comparison gives an analyst a more specific question to investigate: does this reading reflect a change in demand, a meter problem, or water that the utility needs to trace?